Developer Recycling System for CTP Processors

Cuts plate developer usage by 50%

  • Absolutely no loss in quality
  • Processor runs cleaner, less maintenance
  • Reduces discharge of waste developer
  • Fully automatic operation
  • No operator oversight required
  • Small footprint 12"W x 11"D x 20"H
  • Change filters when you change the bath
  • Fast Return-On-Investment

The Plate Chemistry Xtender; (PCX) is an advanced recycling and delivery system that reduces developer usage in CTP plate processors by 50%.

At the heart of the system is a special absorption cartridge that restores seasoned developer to a like new condition.

The PCX is installed in a closed loop with the processor developer bath. Every time the processor replenishment pump is energized the PCX draws seasoned developer from the bath, filters it, blends it with fresh developer and replenishes the blended mixture to the bath.

In most cases the blended mixture of fresh and filtered chemistry is 50/50. The blend can be set to any percentage by adjusting the processor replenishment timer.

Contact us to inquire about a free trial at your facilities

Click here to view the PDF for mor information.

Just Installed - PCX (PLATE CHEMISTRY XTENDER)

Transcontinental Printing - Brampton, ON
They are running thermal energy elite chemistry and plates
Processor: Agfa Elantrix 150HX (Quartz III 150)

Cober Printing Limited
Kitchener, ON
Contact: Mr. Robert Engel (in photo)

CTP PROCESSOR Interplater 135HD
USING CREO POSITIVE PLATES
USING CREO THERMAL POSITIVE DEVELOPER TPD-D

HAVE CUT BACK DEVELOPER USAGE BY 50% PER PLATE WITH NO LOSS IN PLATE QUALITY

Sotek Graphics - Gloucester, ON
Processor: Agfa LP82 Ultra
Chemistry: L5000
Plates: Lat V
Britannia Printers - Toronto, ON
Processor: Agfa Elantrix
Chemistry: Saphira
Plates: Saphira Thermo Plate PN
Allprint Ainsworth - Kitchener, ON
Processor: Kodak Sword Exel NE 34
Developer: Kodak 956 Developer & Kodak Regenerator Replenishment Dev.
McLaren Press Graphics (2 units installed)
Processor: Kodak G7j PT 85 and PT 135
Developer: Kodak 980

Sing Tao Daily - Toronto, ON
Processor: G&J SLP 85 MK
Florida Times Union - Jacksonville, Florida


The absorption cartridge is the only consumable item in the PCX. The cartridge is changed with each developer bath change.

The PCX is a fully automatic system. No monitoring is required and the unit can be easily bypassed for system cleaning. Turning the system off completely removes the PCX from the replenishment system and restores the processor to its original configuration.

It is a stand mounted system designed to fit beneath the plate catch tray or under the processor. The dimensions are 20" high x 12" wide x 11" deep.

Greenflow Environmental Services Inc. distributes, installs and maintains chemical reduction and recycling systems for a broad range of applications. We are committed to the development of environmentally responsible, cost-effective solutions for the graphic arts industry.
Your Name*    
Email Phone*
Note
Security Code*
   

CLICK HERE TO RETURN TO THE PRODUCT GALLERY